200 kVA Generator Rental in UAE | Silent Diesel Generator Hire Dubai

200 KVA Generator

Power Output: 200 kVA Prime (160 kW) and 220 kVA Standby (176 kW) at 0.8 PF.
Engine Platform: Cummins 6CTAA8.3-G2, a 6-cylinder, 8.3-litre turbocharged and charge-air-cooled block purpose-built for this duty class.
Acoustic Canopy: 71-75 dB(A) at 7m, with an enlarged radiator core and extended fan shroud rated for continuous 50°C ambient running.
Turnkey Support: 24/7 mobile engineer dispatch, trailer transport, and on-site commissioning across all seven Emirates.

200 kVA GENERATOR TECHNICAL SPECIFICATIONS

The 8.3-litre Cummins block gives this size class a higher torque reserve relative to its kVA rating than smaller 6.7L-engined sets, which is what underpins its motor-starting capacity. Below is the full build specification confirmed on your test certificate at delivery.

ParameterSpecification
Prime Power Rating200 kVA / 160 kW @ 0.8 PF
Standby Power Rating220 kVA / 176 kW @ 0.8 PF
Continuous Operating Power (COP)182 kVA / 146 kW
Engine Series & ConfigurationCummins 6CTA8.3-G3 / Perkins 1306A-E87TAG4 / FG Wilson P176-3 — 6-Cylinder In-line, Turbocharged & Charge Air Cooled
Alternator TypeStamford UCI274H or Leroy-Somer LSA 44.3, Brushless, Class H Insulation, IP23
Voltage / Phase / Frequency400V / 230V, 3-Phase + Neutral, 50 Hz
Noise Level @ 7m71–75 dB(A), Soundproof Acoustic Canopy
Base Fuel Tank Capacity400–450 Litres, approx. 10–11 hours runtime at 75% Prime Load
Control PanelDeep Sea DSE 7320 (standalone) or DSE 8610 (sync/paralleling), Auto-Start
Main Circuit Breaker3-Pole / 4-Pole Motorized MCCB, Adjustable Overload, Earth Leakage Protection
Dimensions (L x W x H)3,900 mm x 1,300 mm x 2,100 mm
Operating WeightDry: approx. 2,650 kg / Wet (full fluids): approx. 2,950 kg
Handling & MobilitySingle-point lifting eye, forklift pockets, lockable access doors

ESTIMATED FUEL CONSUMPTION MATRIX

The 8.3-litre Cummins block carries a flatter specific fuel consumption curve under partial load than smaller-displacement engines, which keeps the 25-50% band more efficient than its rated capacity might suggest.

Load LevelOutput (kW)Fuel Burn (L/hr)
25% Load40 kW11.5 L/hr
50% Load80 kW21.5 L/hr
75% Load (Optimal Prime)120 kW31.0 L/hr
100% Full Load160 kW41.0 L/hr

Note: Based on diesel density of approx. 0.84–0.85 kg/L; a 3–5% tropical derating applies above 45°C ambient, and on-demand mobile fuel tanker delivery keeps extended runs topped up.

TYPICAL APPLICATIONS FOR 200 kVA GENERATORS IN UAE

This capacity is specifically sized for sites with one dominant high-draw motor plus standard balance-of-plant load, not for powering several large machines simultaneously.

Primary Construction & Industrial Equipment: A single 15-20 ton tower crane hoist motor at DOL start, concrete pump units, 2-3 submersible dewatering pumps running together, and full site office cabins.

Commercial Facility & Backup Scenarios: Mid-rise office floors (G+8 to G+15), standalone supermarkets, and clinic or diagnostic centre backup where imaging equipment needs clean, stable sine-wave power.

HVAC & Temporary Cooling Integration: Matched almost exactly to one 70-80 ton air-cooled package chiller, or four to five 10-15 ton split package AC units running concurrently.

Specialized Sector Application: Mid-size exhibition stands and VIP marquees at DWTC, and instrumentation or control room power during a single-train refinery shutdown package.

Grid Outage & Emergency Support: Sized for a localized DEWA/ADDC feeder trip affecting one building block, where a smaller unit would trip on inrush and a larger unit would run under-loaded all day.

WHAT IS INCLUDED IN OUR 200 kVA RENTAL PACKAGE?

Every rental is delivered as a complete turnkey package, not just the generator set. Here is the full scope of supply included or available on request.

Load-Bank Testing: 100% resistive load-tested certificate issued before dispatch.
Heavy-Duty Power Cables: Certified flexible rubber copper cables, 120 mm² to 150 mm² depending on run length.
Automatic Transfer Switch (ATS): Optional 250A–315A ATS panel for automated emergency failover.
Distribution Boards: Weatherproof MDB fitted with IP67 industrial CEE sockets (16A, 32A, 63A, 125A).
24/7 Technical Support: Dedicated mobile technician coverage and preventive servicing.

RAPID DELIVERY COVERAGE ACROSS THE UAE

Our fleet and technician teams are positioned to reach any Emirate quickly, with offloading and commissioning handled on-site. Delivery timelines below are standard across active rental contracts.

Dubai & Sharjah: Fast 2-hour emergency site delivery and connection.
Abu Dhabi, Mussafah & ICAD: Same-day delivery, electrical setup, and commissioning.
Northern Emirates (Ajman, RAK, UAQ, Fujairah): Scheduled turnkey deployment with mobile crane offloading.

Frequently Asked Questions

Rates depend on duration, location, and fuel inclusion, with longer contracts bringing a lower daily rate. Contact sales@rentalgenerator.ae or (+971) 56 921 3754 for a firm quote.

Yes, the 6CTAA8.3-G2's torque reserve supports a single DOL start up to approximately 45 kW before voltage dip exceeds 15%; larger motors should use a soft starter or VFD.

The cooling package is specified with extra margin for UAE ambient conditions, holding stable output with minimal nuisance tripping. A modest 3–5% derating may apply in peak summer, which we factor into sizing.

Yes, units fitted with DSE 8610 MKII panels synchronize automatically for combined capacity or N+1 redundancy, commonly used where a single 400 kVA set isn't available on short notice.

Rental Generator retains full responsibility for scheduled servicing and breakdown response throughout the contract. The client only handles day-to-day operation and prompt fault reporting.

Need Immediate Power on Site?
Speak with Our Engineers Now