1750 kVA Generator Rental in UAE | Diesel Generator Hire Dubai
A 1750 kVA generator sits above our standard fleet range and is reserved for utility-scale projects where even a 1500 kVA unit would run too close to its limit. At this capacity, it is almost always supplied as part of a multi-unit paralleled power plant rather than deployed alone.
Power Output: Delivers 1750 kVA (1400 kW) of continuous power, matching the output of a dedicated small-scale power station.
Engine Brand: Powered by trusted heavy-duty engines from Cummins, Perkins, FG Wilson, or Mitsubishi/Doosan.
Silent Enclosure: Housed in a Containerized Silent Generator / Heavy-Duty Soundproof ISO 40ft Acoustic Container built for 50°C UAE summer heat.
24/7 Support: Round-the-clock technical assistance, delivery, and maintenance across the UAE.
1750 kVA GENERATOR TECHNICAL SPECIFICATIONS
At this capacity the generator uses a larger-bore V18 engine platform rather than the V16 found in our 1500 kVA units, giving it a genuine step up in output rather than just a tuned version of the smaller block. It ships in a reinforced 40ft ISO container built for continuous multi-month site deployment.
| Parameter | Specification |
|---|---|
| Prime Power Rating | 1750 kVA / 1400 kW @ 0.8 PF |
| Standby Power Rating | 1925 kVA / 1540 kW @ 0.8 PF |
| Continuous Operating Power (COP) | 1591 kVA / 1273 kW |
| Engine Model & Configuration | Cummins QSK60-G9, 18-Cylinder V-Type, Turbocharged & Charge Air Cooled |
| Alternator Brand | Stamford HCI734F or Leroy-Somer LSA 52.2, Brushless, Class H Insulation |
| Voltage / Phase / Frequency | 400V / 230V, 3-Phase, 50 Hz |
| Noise Level @ 7m | 76-80 dB(A), Heavy-Duty Soundproof ISO 40ft Acoustic Container |
| Fuel Tank Capacity | 2,600-2,800 Litres, approx. 7-8 hours running time at 75% load |
| Control Panel | Digital Auto-Start & Synchronizing System (Deep Sea DSE 8610 MKII, Paralleling-Ready) |
| Main Circuit Breaker | Motorized ACB (Air Circuit Breaker), 2900A safety rating |
| Dimensions (L x W x H) | 12,192 mm x 2,438 mm x 2,896 mm (Standard ISO 40ft Container) |
| Weight | Dry: approx. 14,200 kg / Wet (full fuel & fluids): approx. 16,600 kg |
| Mobility & Rigging | ISO corner castings for crane and flatbed lifting, reinforced forklift pockets on base frame |
ESTIMATED FUEL CONSUMPTION MATRIX
This table shows roughly how much diesel the generator uses per hour at different power levels, which is essential for budgeting fuel contracts on utility-scale, multi-month deployments.
| Load Level | Output (kW) | Fuel Burn (L/hr) |
|---|---|---|
| 25% Load | 350 kW | 88.0 L/hr |
| 50% Load | 700 kW | 169.0 L/hr |
| 75% Load (Best Running Level) | 1050 kW | 245.0 L/hr |
| 100% Full Load | 1400 kW | 325.0 L/hr |
Note: At this scale fuel supply is always planned as a dedicated bulk storage and tanker rotation schedule, since relying on the onboard tank alone would mean refuelling multiple times a day at full load.
TYPICAL APPLICATIONS FOR 1750 kVA GENERATORS IN UAE
This capacity is used almost exclusively on projects that need true power-plant-level output, where the generator or a paralleled set of them effectively becomes the project’s main electricity source.
Primary Industry / Work Sites: Powers entire giga-project construction phases with dozens of cranes, full precast factories, and continuous large-scale earthworks and tunnelling equipment.
Commercial & Facility Backup: Serves as complete backup power for major airport terminals, large free zone industrial clusters, and big government or utility complexes during extended planned outages.
Temporary Cooling & HVAC: Can run one very large 580-620 ton central chiller plant, or the combined cooling demand of a large district cooling network segment.
Mega Events & Exhibitions: Acts as a primary power block for World Expo-scale or Olympic-scale event infrastructure, typically paralleled with sister units for full venue coverage.
Oil & Gas, Marine & Grid Support: Used for complete petrochemical complex turnarounds, large LNG terminal support, and as a temporary substitute power station during major national grid upgrades.
WHAT IS INCLUDED IN OUR 1750 kVA RENTAL PACKAGE?
Every rental comes as a complete, ready-to-use package, engineered for integration into a multi-unit power plant setup rather than a single standalone connection.
Load Testing: Certified testing report before delivery to ensure 100% working condition.
Power Cables: High-quality, safe copper cables included for connection, with dual or triple-run configurations sized per your switchgear layout.
Automatic Transfer Switch (ATS): Optional auto-switch box that turns on the generator automatically during power cuts.
Distribution Boards: Safe weatherproof power outlet box for plugging in multiple site feeds.
Maintenance & Service: Free 24/7 technical repair and routine servicing included in the rental.
RAPID DELIVERY COVERAGE ACROSS THE UAE
Wherever your site is located, our team can get this generator delivered, connected, and running quickly.
Dubai & Sharjah: Fast 2-hour emergency site delivery and setup.
Abu Dhabi, Mussafah & ICAD: Same-day delivery, connection, and testing.
Northern Emirates (Ajman, RAK, UAQ, Fujairah): Scheduled transport and safe crane offloading
Frequently Asked Questions
It's almost always rented in groups of two or more and paralleled together, since projects needing this much power typically need several megawatts in total.
Fewer, larger units mean less cabling, fewer footprint points, and simpler synchronization compared to stacking several smaller generators to reach the same total output.
Because this is a specialized, high-demand unit, we recommend booking at least 2 to 3 weeks in advance to guarantee availability and arrange transport logistics.
Yes, we always set up bulk fuel storage alongside this unit, since the onboard tank alone would need refilling multiple times during a full working day.